T3000 Series Integrated Inverter for Elevator
The T3000 Series Integrated Elevator Controller is our company’s new-generation integrated elevator controller. Developed and manufactured in-house with targeted technical upgrades, it is built on extensive proven field application experience and tailored to the latest evolving features of the elevator industry.
The main features are as follows:
More advanced
*It takes direct position as the control object, and is equipped with the function of automatically generating motion speed profiles for multi-floor operation.
*It features multi-core redundant control technology, built with advanced CAN bus, Modbus and Industrial IoT (IIoT) communication capabilities.
*It is equipped with a built-in precise real-time clock, providing rich time-sharing control functions to achieve energy-saving control and intelligent building management.
*Support multiple flexible emergency rescue operation plans.
*It is equipped with the function of automatic detection and targeted operation control for short-landing travel.
*UCMP, brake force detection function.
*With less than 8 units having group control function.
More user-friendly
*Integrated control and drive, compact structure, facilitating the realization of small-room and no-room designs.
*The function parameters are easy to operate and convenient for debugging.
*Support multiple debugging methods: P12 upper computer software, operation panel, remote debugging (supports Bluetooth, WIFI).
*Equipped with a multifunctional keyboard, it makes the inspection, maintenance and debugging of the elevator a simple and easy process.
*It is equipped with an intelligent load weighing auto-tuning function.
*It features an elevator health check function, including automatic balance coefficient detection and traction slip measurement.
Safe and reliable
*Multiple safety protections, in compliance with GB/T7588.1/2 - 2020 standards.
*The hardware and software have been designed with fault-tolerant features, featuring multiple types of fault handling mechanisms to minimize the occurrence of accidents to the greatest extent.
*Ensuring safe operation, with professional drive manufacturing technology, strong environmental adaptability, and comprehensive resistance to grid fluctuations, dust, high temperatures and lightning.
*Multi-core control operation, braking, and STO function.
More comfortable
* Without a weighing sensor, flexible start-up and docking can be achieved.
* High-performance vector control fully exploits the motor's capabilities, thereby providing a greater sense of comfort.
More economical
*True integration leads to a simpler system, significantly reducing peripheral wiring, making it economical and easy to use, and enhancing the safety and stability of the elevator.
*Bus technology minimizes the quantity of traveling cables.
*The accessories are designed in a modular way, featuring a wide range of flexible and diverse options. They can be combined to meet the exact needs of customers.
*Built-in simplified group control software, enabling dual-machine group control without a group control board.
List of Basic Functions
| Function Name | Function Description | Note |
| Regular operation function | ||
| Full Collective Operation Function | In Automatic Operation or Driver Mode, the elevator automatically responds to hall call button signals while handling car calls during operation. Passengers on any served floor can summon the elevator by registering the up or down button signals. | PE-00 'Collective Selection Mode' |
| Service Floor | The standard model supports service for 40 floors. It can be upgraded to cover more floors through non-standard modification. | - |
| Door opening time setting function | The system automatically distinguishes different states such as automatic door opening, command door opening, door protection opening, and delayed opening, and maintains the opening time for each state according to the preset time. | P11 Parameter Settings |
| Door opening with delay function | In the automatic operation mode, when pressing the door opening delay button inside the cabin, the elevator will delay closing the door, which is convenient for transporting goods and other purposes. | P11.14 'Door Opening Delay Time' |
| Service Floors for Doors | The system can individually select the required service floors for each door as needed. | P11.02/03/04/05 P11.18/19 |
| The door close button enables early door closing. | In the automatic operation mode, when the door is kept open, the door can be closed in advance by pressing the close button, thus improving efficiency. | - |
| Floor Display Settings | The system allows each floor to use any combination of numbers and letters for display, facilitating use in special situations. | PE group parameter settings |
| Light Curtain Signal Self-Diagnosis | When an obstacle blocks the middle of the doors during the door closing process, the light curtain protection is activated, and the elevator switches to door opening. However, the light curtain protection is inactive during Fire Service Operation. | - |
| Auxiliary control compartment function | When a main control box is available, an auxiliary control box can also be optionally equipped. The operating functions of the auxiliary control box are the same as those of the main control box. | - |
| Independent control function for the front and rear doors | When there are two doors, the automatic control of both doors can be achieved according to the specific needs of the users. | - |
| Repeat closing function | After the elevator door has been closing for a certain period of time, if the door lock has not yet closed, the elevator will automatically open and then repeat the closing process. | P11.08 'Closing Time for Protection' |
| Instruction Independence Function | When equipped with main and auxiliary car operation panels (COP), the auxiliary COP can be configured for either rear door command input or accessibility command input. In automatic operation mode, the system delivers differentiated responses to commands from both the main and auxiliary COPs, with independent control for door opening and closing. | - |
| Voice announcement function | During the operation of the elevator, it automatically broadcasts information such as the running direction and the floor stops it is about to reach to the passengers. | - |
| Automatic Leveling, Commissioning-Free | The system adopts a dual signal processing method combining floor pulse counting and upper/lower leveling feedback, enabling automatic and accurate leveling, which truly realizes commission-free leveling. | - |
| Acceleration-phase car stop response | The system allows car stop during elevator acceleration and automatically responds to the corresponding service floor commands. | - |
| Down Collective Control Operation Function | In either Automatic mode or Attendant mode, during elevator operation, the elevator responds to car call signals while only responding to hall down call button signals. | - |
| Idle Return to Base Station Function | In Automatic Operation mode, if no car calls or hall calls are received within the preset time, the elevator will automatically return to the set parking base station and wait for passengers. | P9-00 'Idle Parking Time' |
| Stop Reassignment Function | If the door fully open signal remains invalid after the elevator door has been continuously open beyond the door open protection time, the elevator will switch to the door closing state. After the door is closed, the elevator will automatically register the next landing for operation and display Fault E55. | - |
| Forced Door Closing Function | When the Forced Door Closing Function is enabled, if the elevator fails to close the door within the set time due to the actuation of the light curtain or safety edge, the elevator will enter the forced door closing state, close the door slowly, and emit an audible prompt. | - |
| Erroneous Command Cancellation Function | For car calls, passengers may cancel an incorrectly registered command by pressing the command button twice consecutively. | - |
| Service Floor Setting Function | The system can flexibly deactivate or activate one or more elevator service floors as required. | P6-05/06/35 |
| Independent Operation | The elevator does not accept hall calls, and the doors are closed manually.In group control mode, it disconnects from the group control system and operates independently. | Signal Input: Command Board JP23 |
| Attendant Operation Mode | When entering Attendant Operation Mode, all corresponding elevator operations are controlled and performed by the attendant. | Signal Input: Command Board JP21 |
| Low-speed Self-rescue Function | When the elevator is in the non-inspection state and not stopped within the landing zone, it will automatically run at low speed to the landing zone and open the door as long as the safety requirements for operation are met. | - |
| Door Control Selection Function | According to the type of door operator used, the system can flexibly set the mode of whether to continuously output commands after the door reaches the fully open position or fully closed position. | - |
| Car Arrival Chime | After the elevator arrives at the destination floor as requested, a prompt signal will be sent from the car top plate. | - |
For more detailed functions, please refer to the instruction manual.
| Item | Specification | |
| Input | Phase/voltage/frequency | Single phase220-240V、50/60HZ |
| Three phase 380/220/480V、50/60HZ | ||
| Permissible voltage variation | -10~+10% | |
| Permissible frequency variation | -5~+5% | |
| Output | Voltage | 0-220VAC/0-380VAC |
| Frequency | 0-99HZ | |
| Output Frequency Resolution | 0.01HZ | |
| Control character | Maximum floor | 48 |
| Elevator speed | ≤4.00m/s | |
| Group control quantity | ≤8 | |
| Communication method | CAN | |
| Control method | Vector control with PG card | |
| Starting torque | Load-dependent, max. 200% | |
| Speed control range | 1:1000 (Vector Control of PG) | |
| Speed control accuracy | ±0.05%(Vector Control of PG) | |
| Control character | Torque limit | 200% |
| Torque accuracy | ±5% | |
| Frequency control range | 0-99HZ | |
| Frequency accuracy | ±0.1% | |
| Frequency setting resolution | 0.01HZ/99HZ | |
| Brake torque | 150% - External Pullback Brake Resistor | |
| Deceleration and acceleration time | 0.1~8S | |
| Carrier frequency | 2-16KHZ | |
Specifications of the T3000 Series—Standard type model
| Controller model | Power capacity (in KVA) | Input current A | Output current A | Matching motor KW |
| Single-phase 220V, range 220~240V, 50~60Hz | ||||
| T3200-1R5G-2 | 3.2 | 9.2 | 5.2 | 1.5 |
| T3200-2R2G-2 | 4.5 | 13.3 | 7.5 | 2.2 |
| T3200-3R7G-2 | 6.7 | 17.9 | 10.3 | 4 |
| T3200-5R5G-2 | 7.6 | 31.3 | 19 | 5.5 |
| T3200-11G-2 | 18 | 42.6 | 27.7 | 11 |
| T3200-15G-2 | 20 | 52.6 | 34.6 | 15 |
| Three-phase 220V, range 220~240V, 50/60Hz | ||||
| T3200-3R7G | 7.6 | 20.5 | 18 | 4 |
| T3200-5R5G | 10.2 | 29 | 27 | 5.5 |
| T3200-7R5G | 13.5 | 36 | 33 | 7.5 |
| T3200-11G | 19.5 | 41 | 39 | 11 |
| T3200-15G | 25 | 49 | 48 | 15 |
| T3200-18R5G | 28.5 | 62 | 60 | 18.5 |
| T3200-22G | 32 | 76.4 | 74 | 22 |
| Three-phase 380V, range 380~440V, 50/60Hz | ||||
| T3400-3R7G | 8 | 10.5 | 9 | 3.7 |
| T3400-5R5G | 11.5 | 14.8 | 13 | 5.5 |
| T3400-7R5G | 15 | 20.5 | 18 | 7.5 |
| T3400-11G | 22 | 29 | 27 | 11 |
| T3400-15G | 29.7 | 36 | 33 | 15 |
| T3400-18R5G | 37.6 | 41 | 39 | 18.5 |
| T3400-22G | 45 | 49.5 | 48 | 22 |
| T3400-30G | 53 | 62 | 60 | 30 |
| T3400-37G | 40.8 | 77 | 75 | 37 |
| T3400-45G | 52 | 93 | 91 | 45 |
| T3400-55G | 62.5 | 113 | 112 | 55 |
| Three-phase 480V, range 440 - 500V, 50/60Hz | ||||
| T3400-3R5G-5 | 9 | 10.5 | 9 | 3.7 |
| T3400-5R5G-5 | 13 | 14.8 | 13 | 5.5 |
| T3400-7R5G-5 | 17 | 20.5 | 18 | 7.5 |
| T3400-11G-5 | 25 | 29 | 27 | 11 |
| T3400-15G-5 | 33 | 36 | 33 | 15 |
| T3400-18R5G-5 | 43 | 41 | 39 | 18.5 |
| T3400-22G-5 | 51 | 49.5 | 48 | 22 |
| T3400-30G-5 | 61 | 62 | 60 | 30 |
| T3400-37G-5 | 65 | 77 | 75 | 37 |
T3000 Specification Parameters - Specialized for Villa Elevators
| Controller model | Power capacity (in KVA) | Input current A | Output current A | Matching motor KW |
| Single-phase 220V, range 220-240V, 50-60Hz | ||||
| T3200-1R5G-LJ | 3.2 | 9.2 | 5.2 | 1.5 |
| T3200-2R2G-LJ | 4.5 | 13.3 | 7.5 | 2.2 |
| T3200-3R7G-LJ | 6.7 | 17.9 | 10.3 | 4 |
| Three-phase 220V, range 380-440V, 50-60Hz | ||||
| T3400-3R7G-LJ | 8 | 10.5 | 9 | 3.7 |
| T3400-5R5G-LJ | 11.5 | 14.8 | 13 | 5.5 |
| T3400-7R5G-LJ | 15 | 20.5 | 18 | 7.5 |